Mep 803a amps

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site.

mep 803a amps

Forums Bookmarks New posts Search forums. What's new New posts New profile posts Latest activity. Members Current visitors New profile posts Search profile posts.

Log in Register. Search titles only. Search Advanced search…. New posts. Search forums. Log in. For a better experience, please enable JavaScript in your browser before proceeding. Thread starter Rapracing Start date Feb 3, Steel Soldiers is supported by: 1 2 3 … Go to page.

Rapracing New member. How many of you have these units? How is it working for you?

MEP802A – MEP812A Manuals

What would be a good price on one? I'm just exploring the idea right now. Knuckles New member. I have an a I just picked up. I'm still going through it, but it looks like a great unit. I have a a hooked up to my house and it has been great. The a is a tank compared to the a, although I'm not sure if that makes it better.

Hard to tell what a good price on the a is - they are rare and it really depends on the unit - condition hours etc. Hopefully not breaking any rules here - but there are a bunch of s available right now. ETN New member. I had an A for a while and sold it. I had to replace the head gasket so I thought why not? In general they are really great machines. Onan sold an enclosed civilian model too. So Parts are available from multiple sources including onan and Lister Petter.

They don't have the overload that the has but they are very quiet, civilized and have a nice panel and a big diagnostic plug that can be used with just a meter to identify a variety of circuits. The fuel tanks frequently leak at the remote drain connection.

This is a major headache to fix as the tank does not come out easily. I now plastic weld that hole shut because the fuel is readily drained by siphoning. The cooling systems are subject to need radiator caps replaced and head gaskets can be a problem.

When you look at a unit or photos look for sign of white coolant tracking at the head joint on the starter side.You can help improve this manual. If you find any mistakes or if you know of a way to improve these procedures, please let us know. Louis, MO Instructions for sending an electronic may be found at the back of this publication immediately preceding the hard copy Section I. Electrical System …………………………………………………………………………………….

Batteries and Cables …………………………………………………………………………………… 1 Slave Receptacle and Cables ………………………………………………………………………. Access Doors and Covers ……………………………………………………………………………. Control Box Assembly…………………………………………………………………………………. Output Box Installation ………………………………………………………………………………. Assembly …………………………………………………………………………………………. Muffler Assembly ……………………………………………………………………………………… 14 Air Cleaner Assembly………………………………………………………………………………… 15 Group 06 Coolant System ……………………………………………………………………………………………….

Radiator and Hoses …………………………………………………………………………………. Fuel Tank, Pumps and Lines ………………………………………………………………………. Oil Drain Line…………………………………………………………………………………………… 18 Group 09 Engine Accessories …………………………………………………………………………………………. Frequency Adjust Cable ……………………………………………………………………………. Skid Base Assembly …………………………………………………………………………………. Load Terminal Board Assembly …………………………………………………………………… 22 Group 12 Generator Assembly ………………………………………………………………………………………. Generator Installation………………………………………………………………………………… 23 Generator Assembly, 60 Hz ………………………………………………………………………… 24 Generator Assembly, Hz ……………………………………………………………………….

Military Surplus Generator Test Run on Off Grid System

Engine Installation……………………………………………………………………………………. Section III. National Stock Number Index ………………………………………………………………….

MEP802A – MEP812A Manuals

How you get an item. Explanations of source codes follows:. They are authorized to the category indicated by the code entered in the 3rd position of the SMR code.

They are part of a kit which is authorized to the maintenance category indicated in the 3rd position of the SMR code. The complete kit must be requisitioned and applied. The parts that make up the assembled item must be requisitioned or fabricated and assembled at the level of maintenance indicated by the source code.

If the 3rd position code of the SMR code authorizes you to replace the item, but the source code indicates the items are assembled at a higher level, order the item from the higher level of maintenance. Order its next higher assembly.

mep 803a amps

Refer to the NOTE below. XD — Item is not stocked.

mep 803a amps

The maintenance codes are entered in the third and fourth positions of the SMR code as follows:. The maintenance code entered in the third position will indicate authorization to the following levels of maintenance. H — General support maintenance can remove, replace, and use the item. L — Specialized repair activity can remove, replace, and use the item. H — General Support is the lowest level that can do complete repair of the item.

L — Specialized repair activity is the lowest level that can do complete repair of the item. D — Depot is the lowest level that can do complete repair of the item.Why do we specialize in these units? For the government or commercial customer, the quality of these units is unsurpassed. For all segments of our business, GMG helps establish a supply chain for these units to streamline the acquisition of refurbished generators and new parts. GMG is committed to establishing a comprehensive parts supply chain for the generators we sell and service.

We welcome the opportunity to establish a long-term relationship with you, whether you are government, supply-chain professional, NGO non-governmental organizationsmunicipality, non-profit or corporation. We have recently obtained approvals from the U. Department of Defense, the U. Department of State and the U. Department of Commerce specifically, the Bureau of Industry and Security to export demilitarized generators globally with specific exceptions.

Have an mepa. Runs fine and putting out power at the lugs, but the convenience plug has no power. Any suggestions? Hello guys I have a 15kw trailer mounted gen with hrs on it. When doing to start on master switch all I get is a click from the injector pump. I can jump across the what I am calling the starter solenoid that is in the upper right hand fwd circuit box. I called Monday and left a voice mail. If I am on right path plz advise. Thanks, Ralph All generators need manual shipping quote.

Yes, we can send you photos, but we are out of stock right now. We can reserve the next MEPA for you if you put a deposit down on it.Depends on the tank and what the available fittings are on the tank. Do you have specs for the tank? Do you just need parts or do you need onsite labor. We do not do travel calls much, but can schedule with lead time. I have a 20gal aux fuel tank that I need hooked to a met a.

Can you do this, I live in Shrewsbury,Vermont. Davis Terrill just installed a remote start from you folks. I am disabled and the extra fuel capacity. Any suggestions? Check the entire circuit for cooling temp. Ensure ground is good and connections good.

You may need a new temp sensor. CBs get tired with age. Certainly you can jump the leads and just try out a fresh CB to see if it too pops. I had a mouse problem in the control box area where I need to replace chewed up and missing wiring. Is the unit shaking or are the electrical output legs not reading correctly? Make sure that the engine mounts are secure and make sure the dials on the control box are configure and set properly e. I do not know the history.

It shows only 3 hrs on the hobs. Engine runs steady but overall unit is seriously out of balance. I am trying to determine the problem; engine or generator. Anybody seen this problem before? Sorry but we have a unit thats the same model and we get the same problem. The CB1 keeps poping and we cant figure it out. Wanted to know if it was ever figured out.

Have you checked all the grounds? Is the unit grounded? Look for any loose wires in the control panel. Ensure that your batteries are configured properly for 24v. Is your master breaker off when you do this?All items sell regardless of price, inventory added daily. Purple Wave is the easiest, most straightforward way to buy and sell used equipment. Generators and Light Plants. Purple Wave is selling a used Generator Set in Oklahoma.

Next Bid. Set Max. Bids GF Item Details. Location Info. View map Item Details: Mark Meyer at mmeyer clevelandcountyok. Removal Details: Mark Meyer at mmeyer clevelandcountyok. Buyer is responsible for all loadout arrangements. Removal Deadline: December 31, see auction details. The buyer's premium will be included in the price against which applicable sales taxes are calculated. No reserve This item will sell without reserve to the highest bidder. Payment Information. Payments must be made within two business days after the auction.

Payment Details. Shipping and Transportation. A separate list of other shipping vendors is available by contacting auction purplewave. Find Similar.

mep 803a amps

Bid Increments. Bid History.The MEP A is fully enclosed and self contained, it weighs lbs dry, and lbs with a full fuel tank. The MEP A engine is an Onan, naturally-aspirated, four cylinders, four cycle, and liquid cooled diesel engine. The engine idle speed is RPM. The horsepower rating is The diesel engine has an oil capacity of 5. The cooling system has a capacity of 8. The MEP A will consume. When the MEP A is connected to an auxiliary fuel system, it will be continually replenished.

It has a 24VDC cranking system. The 24VDC comes from two 12V batteries, connected in series. Will be test run but no load tested. Sold as is. Parts we offer for sale can be exported. Where necessary, required export approvals and licenses, U.

MEP803A Total Output Amps

We can provide container loads of parts, loaded and shipped from our facility. Call or email with any questions or needs. Tires, Wheels and Accessories 9. Vehicles Special Parts Special.

Skip Navigation Links. NSN :. Part :. This item is only available in this condition Used. No alternate conditions are available at this time.Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors.

Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Forums Bookmarks New posts Search forums. What's new New posts New profile posts Latest activity.

Members Current visitors New profile posts Search profile posts. Log in Register. Search titles only. Search Advanced search…. New posts. Search forums. Log in. For a better experience, please enable JavaScript in your browser before proceeding. Steel Soldiers is supported by:. Sitting on a pallet in Tampa. Was doing some calculations and can see that 10kw is not a safe output figure.

Some of these can go to 14kw and run all day long. This begs the question that at 14kw VAC means a feed output of 58Amps. Much more than the rated output of 51 Amps given as the standard output at.

While at Why wouldn't you want to use the full output if the genset runs with no issues? Most people say the 50A stuff is rated for far higher than 50A. You can get used Hubbell on ebay. I put the Elecdirect female pin and sleeve plug on the other end.

I have the corresponding inlet on the wall. It's IP67 watertight and locks in nicely. FWIW - the pin and sleeve stuff is much larger than I thought but seems heavy duty. It still cost a lot more probably double compared to 50A parts but I wanted it rated for the current I could draw, wanted twist lock, and wanted the watertight rating. I have a 60 A breaker to protect that wiring because as you say, the breaker cost isn't that big of a deal.

Overall, I don't think breaker costs increases much until you get to 70 A. How much continuous load do you expect to put on the generator? DieselAddict said:. Dock Rocker Member. USAMilRet said:.


0 thoughts on “Mep 803a amps

Leave a Reply

Your email address will not be published. Required fields are marked *

You may use these HTML tags and attributes:

<a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <s> <strike> <strong>